Inspection Information
Facility Name: Towne Park Apartment
Facility Type: Pool
[?] Inspection type: Follow-up
Inspection date: 14-June-2018
No violations were documented at the time of inspection.
The following violation(s) have been corrected since the last inspection.
3701-31-04 (B)(1)(l)/Electrical hazards shall not exist.
At the time of inspection, the underwater lights and pump room equipment were not observed on a GFI breaker or outlet.
To prevent electrical hazards, place the underwater lights and pump room equipment on a GFI.
3701-31-04 (C)(2)/pH is within 7.2 to 7.8
At the time of inspection, the pH was observed at 7.0.
To ensure the chlorine properly disinfects the pool, the pH shall be between 7.2 and 7.8. Increase the pH of the pool.
Comments
- Reinspection was conducted to check the status of the GFI breaker installation, the pH, alkalinity, and flow meter. At the time of inspection, the pH was observed at 7.2 while the alkalinity was observed at 70. New GFI breakers were observed and the flow meter was observed functional and reading 95 gpm. All violations from the reinspection on 5/25 and standard inspection on 5/30 were corrected and satisfactory.