Inspection Information | Facility Name: | Tipp Aquatic Center (Activity) |
---|---|
Facility Type: | Special Use Pool |
[?] Inspection type: | Follow-up |
Inspection date: | 13-July-2018 |
No violations were documented at the time of inspection. |
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 ( D )(6)(a)/ORP reading shall be 650 millivolts or greater. At the time of inspection, the automatic chemical controller was observed reading an ORP of 455. To ensure the free chlorine is at or above 1.0 ppm, the ORP shall be at or above 650. Have the ACC inspected to ensure the ORP is at or above 650. |
3701-31-04 (B)(1)(c)/Minimum disinfection residual shall be maintained as required. At the time of inspection, the free chlorine was observed at 0.0 ppm. To disinfect the pool, the free chlorine shall be at or above 1.0 ppm. At the time of inspection, the pool had yet to be opened. The PIC stated the pool would remain closed until the free chlorine would be at or above 1.0 ppm. |
Comments |
---|
- Reinspection was conducted due to report dated 07/12/2018. At the time of inspection, the ORP was observed at 735 while the chlorine residual was observed at 1.4 ppm. All violations were corrected and are satisfactory. |