Inspection Information | Facility Name: | Towne Park Apartment |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Follow-up |
Inspection date: | 29-July-2016 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(1)(e) Critical Repeat Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection. Observed feeders were not operational during pH and ORP alarm. Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation. |
3701-31-04 (B)(6) Repeat Oberserved water leak. Equipment was not maintained per manufacturers specifications. Reapir water leak properly. All equipment must be maintained in accordance with the manufacturers specifications. |
3701-31-04 (B)(6)(k) Critical Repeat Outlet drain covers were not secure to the pool wall. Secure the outlet cover immediately to prevent entrapment/evisceration. |
3701-31-04 (B)(6)(o) Repeat Observed ladders that were unsecure. Repair or replace the ladders/stairs/steps so that they are secured and in good repair. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. Treat the pool water so that the pH is within the acceptable range. |
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 ( D )(6)(a)/ORP reading shall be 650 millivolts or greater. ORP reading was below 650 mv Have the ACC unit inspected to determined why the ORP is low. |
3701-31-04 (B)(1)(l)/Electrical hazards shall not exist. Observed electrical cord plugged into wall while in water in pump room. Do not operate the pool when an electrical hazard is present and fix water leak. |
3701-31-04(D)(6)(a)(2)/Pool free chlorine disinfectant residual shall be above 1 ppm. Pool free chlorine disinfectant residual was below 1 ppm. Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. |
Comments |
---|
This pool has had continuos repeat violations on the function of the auto controller. The operator must prove that the auto-controller is functioning properly, until then the pool chemistry must be taken every 4 hours to ensure proper water chemistry. This auto-controller must be maintenanced properly, or must be reset to properly react to the water chemistry properly. Currently the auto-controller turns off the feeder when an alarm goes off, even when the alarm is when the feeder needs to feed. Place label outside of phone case that states "Push and hold button until connected with 911 operator." |