Inspection Information | Facility Name: | Towne Park Apartment |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 28-June-2019 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(1)(c) Corrected During Inspection Critical The free chlorine was observed at 0.6 ppm. To properly disinfect the pool, the free chlorine shall be at or above 1.0 ppm. At the time of inspection, the pool was closed, the ORP on the automatic chemical controller was increased, and chlorine was added to the pool. Continue to cease operation of the pool until the free chlorine is at or above 1.0 ppm. |
3701-31-04 (C)(2) At the time of inspection, the pH was observed below 7.0. For the chlorine to properly disinfect the pool the pH shall be between 7.2 and 7.8. Once the chlorine is above 1.0 ppm, increase the pH, if necessary. |
3701-31-04 (C)(3) At the time of inspection, the alkalinity was observed at 30 ppm. The alkalinity shall be at or above 60 ppm to ensure the water is balanced. Increase the chlorine and pH and then increase the alkalinity to at least 60 ppm. |
3701-31-04(D)(6)(a)(2) Corrected During Inspection Critical The free chlorine was observed at 0.6 ppm. The pool was closed, ORP on the automatic chemical controller was increased and chlorine was added to the pool. Continue to cease operation of the pool until the free chlorine is at or above 1.0 ppm. |
Comments |
---|
- Reinspection will be conducted between 7/1/19 and 7/3/19 to recheck the water quality readings |