Inspection Information | Facility Name: | Holiday Inn Express Troy |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 07-February-2017 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(ii) Combined chlorine was not tested daily at pool side prior to use. Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(6) Equipment was not maintained per manufacturers specifications. Observed flow meter was stuck, showing that there was flow when there was no water running through the pipe. All equipment must be maintained in accordance with the manufacturers specifications. |
3701-31-04 (E)(3)(b) The unguarded pool was in use without the "Children must be supervised" and/or "Swimming alone is not recommended" signs posted. Post the "Children must be supervised" and/or "Swimming Alone is Not Recommended" signs at all times the pool is available for use. |
Comments |
---|
Pool was closed upon inspection. Equipment for the pool is currently being worked on, as well as the pool itself. The covers for the safety devices on the bottom of the pool are being repaired. Pool operator does need to prove that they covers do meet VFB certification during the next inspection. Flow meter was stuck and either needs to be cleaned effectively or replaced. The combined chlorine of the pool needs to be recorded on a daily basis in order to have the correct total chlorine. There will be a re-inspection in three weeks to check chemicals and ensure that everything is working properly. |