Inspection Information | Facility Name: | Comfort Inn & Suites |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 15-February-2023 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(i) At the time of inspection, according to the records provided, the free chlorine was observed not being tested prior to opening. To ensure adequate amount of chlorine in pool prior to opening, the free chlorine shall be tested prior to opening. |
3701-31-04 (B)(4)(a)(iii) At the time of inspection, according to the records provided, the pH was observed not being tested prior to opening. To ensure the pH is within normal limits prior to opening, the pH shall be tested prior to opening. |
3701-31-04 (B)(4)(c) At the time of inspection, according to the records provided, the safety vacuum release system and automatic chemical controller were observed not being tested/documented as required. To ensure proper function, the SVRS and ACC shall be tested and documented monthly. During the inspection, the owner properly tested both the SVRS and ACC. |
3701-31-04 (C)(2) At the time of inspection, the pH was observed below 7.0. To ensure the chlorine is properly disinfecting the pool, the pH shall be between 7.2 and 7.8. Reduce the pH to within normal limits. |
Comments |
---|