Inspection Information | Facility Name: | YMCA Robinson Branch (SPA) |
---|---|
Facility Type: | Spa |
[?] Inspection type: | Standard |
Inspection date: | 10-July-2019 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(c) SVRS/APSOS/ACC test results/ service records were not maintained. Operator has not been regularly testing SVRS system The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. Observed pH of 7.0 Treat the pool water so that the pH is within the acceptable range. |
3701-31-04 (C)(3) Total alkalinity was less than 60 ppm. Observed alkalinity at 30PPM Raise the total alkalinity to at least 60 ppm. |
Comments |
---|
-At the time of inspection, all safety equipment and proper signage present and in good repair -Alkalinity and pH low. Increase levels Lifeguard records present and current Inspection conducted with Shane Snapp |