Inspection Information | Facility Name: | Comfort Inn & Suites |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 27-November-2023 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(ii) According to the records provided, the combined chlorine was observed not being tested prior to opening and every 12 hours. To ensure combined chlorine is at or below 1.0 ppm, the combined chlorine shall be tested prior to opening and every 12 hours. Ensure the combined chlorine is tested according to requirements. |
3701-31-04 (B)(4)(a)(iv) According to the records provided, the water temperature was not observed being tested. To ensure the water is below the required maximum temperature of 90 F, the water temperature shall be tested daily. Ensure the water is tested and documented daily. |
3701-31-04 (B)(4)(a)(vi) According to the records provided, total alkalinity was observed not being tested weekly. To ensure the alkalinity is at or above 60 ppm, total alkalinity shall be tested weekly. Ensure alkalinity is tested and documented weekly. |
3701-31-04 (B)(4)(c) Repeat According to the records provided, the automatic chemical controller (ACC) and safety vacuum release system (SVRS) were observed not being tested/documented monthly. To ensure the ACC and SVRS function, the two pieces of equipment shall be tested monthly. Ensure the ACC and SVRS are tested and documented monthly. |
3701-31-04 (C)(2) Repeat At the time of inspection, the pH was observed at 7.0. To ensure chlorine is able to properly disinfect, the pH shall be between 7.2 and 7.8. Increase the pH to within normal limits. |
3701-31-04 (C)(3) At the time of inspection, the total alkalinity was observed at 50 ppm. To ensure the pH is balanced, increase the pH to at or above 60 ppm. |
Comments |
---|
- At the time of inspection, all the safety equipment was present along with the proper signage. |