Inspection Information | Facility Name: | Holiday Inn Express Troy |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 03-August-2022 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(i) Repeat According to the records provided, the chlorine was only being tested prior to opening. To ensure proper free chlorine when an automatic chemical controller is not present, the free chlorine shall be tested every 4 hours. Begin the testing of the free chlorine every 4 hours. |
3701-31-04 (B)(4)(a)(ii) Repeat According to the records provided, the combined chlorine was not observed being tested prior to opening and every 4 hours. Since the pool is without an automatic chemical controller, the combined chlorine shall be checked and documented every 4 hours. Begin checking the combined chlorine prior to opening and every 4 hours. |
3701-31-04 (B)(6)(p) Repeat The tile around ladder and stair handrails were observed in disrepair and without grout. Also, grout was observed missing from between tiles around the pool. To prevent the pooling of water, add grout. |
3701-31-04 (D)(02) Critical At the time of inspection, sodium hypochlorite pucks were observed in the skimmer baskets. To ensure proper residual chlorine levels, the pool shall be connected to a functioning continuous disinfection system and tested according to 3701-31-4(B)(a)(i). Cease the hand feeding of chlorine and ensure the disinfection is functioning properly. |
3701-31-04 (E)(2)(e) At the time of inspection, the emergency telephone was nonfunctional. To ensure authorities are able to contacted during an emergency, an emergency telephone shall be present and functional. Repair or replace the emergency telephone. |
3701-31-04 (E)(3)(b) Repeat At the time of inspection, a "Swimming alone is not recommended" sign was not observed posted. Post a "Swimming alone is not recommended" sign. |
Comments |
---|
- Install a weir (flap) on the skimmer located on the window side of the pool. |