Inspection Information | Facility Name: | Village of Concord |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Follow-up |
Inspection date: | 13-August-2018 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(i) Repeat At the time of inspection, the pool was observed open and the water quality readings were not observed taken and/or documented. To ensure the water quality readings are within normal limits prior to usage, the testing of the water shall be conducted prior to opening and with a automatic chemical controller, every 12 hours. Ensure the water is tested prior to opening. |
3701-31-04 (C)(2) Repeat At the time of inspection, the pH was observed at 7.0. To ensure the chlorine is working properly, the pH shall be between 7.2 and 7.8. Increase the pH of the pool to within normal limits. |
3701-31-04 (C)(3) Repeat At the time of inspection, the alkalinity was observed at 20 ppm. To ensure the pool is properly balanced, the alkalinity shall be at or above 60 ppm. Increase the alkalinity of the pool. |
3701-31-04 (D)(7)(d) Critical Repeat The flow switch on the automatic chemical controller was observed not recently tested. To ensure the ACC shuts off when the flow ceases, the automatic chemical controller flow switch shall be tested monthly. Test the ACC shut off valve. |
3701-31-04 (E)(2)(a)(ii) Repeat A ring buoy was not observed at the time of inspection. To ensure there is a flotation device present for rescue, a ring buoy shall be available. Provide a ring buoy. |
3701-31-04 (E)(2)(a)(iii) Repeat At the time of inspection, the spine board was not observed present on the deck surface. To ensure stabilization, a spine board shall be present when the pool is operational. Place a spine board near the pool. |
Comments |
---|
- Reinspection was conducted due to report dated 08/02/2018. At the time of inspection, all the violations from the previous inspection were observed and remained. Ensure the automatic chemical controller is functioning properly and indicates audibly and visually if a reading is not within normal limits (the ORP or pH are out of range). The above violations will be checked during the next standard inspection. |