3717-1-04.4(J) / Mechanical warewashing equipment - wash solution temperature.
Critical The wash solution in the spray type warewasher is not being maintained at the proper temperature and observed between 95F and 100F.
The temperature of the wash solution in spray type warewashers that use hot water to sanitize may not be less than: (a) For a stationary rack, single temperature machine, 165˚F; (b) For a stationary rack, dual temperature machine, 150˚F; (c) For a single tank, conveyor, dual temperature machine, 160˚F or (d) for a multitank, conveyor, multi-temperature machine, 150˚F. The temperature of the wash solution in spray-type warewashers that use chemicals to sanitize may not be less than 120˚F. Correct By: 07-Feb-2014
3717-1-04.4(N) / Manual and mechanical warewashing equipment, using chemical sanitization - temp., pH, concentration, and hardness
Critical Sanitizer in the dish tank observed in a strong concentration of 200ppm chlorine. Sanitizer for spray bottles used to sanitize tables and food contact surfaces observed in a very strong concentration greater than 500ppm quaternary ammonia.
A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation shall meet the criteria specified under paragraph (E) of rule 3717-1-07.1 of this code, and be used in accordance with the EPA-approved manufacturer's label use instructions. Chlorine in dishtank that is operated above 120F should be in a conentration between 25ppm and 50ppm. Quaternary ammonia sanitizer for spray bottle must be used at 200ppm as indicated by manufacturer. Correct in 1 day. May need to contact service company to have dispensing devices properly calibrated. Correct By: 07-Feb-2014
3717-1-06.1(A) / Floors, walls, and ceilings.
Repeat Two ceiling panels that were replaced after fire are absorbent and not easily cleanable. Replace with proper ceiling tile.
Floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable.
3717-1-06.4(A) / Repairing.
The area of wall above fish fry line is peeling paint and needs resufaced. Resurface with a durable material that can be washed frequently and with stand heat and vapors from fryers.
The physical facilities shall be maintained in good repair.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 06-February-2014
Comments |
---|
Cold and hot food sampled observed held in proper temperature of 41F or below and 135F or above. Prep areas kept clean. Gloves, thermometers, and hair restrains in use. |