3717-1-03.4(E) / Cooling methods - temperature and time control.
Critical Observed improper method for cooling TCS foods. Chili was being cooled in large containers not condusive to rapid cooling.
To prevent the growth of pathogens: (1) Cooling shall be accomplished in accordance with the time and temperature criteria by using one or more of the following methods based on the type of food being cooled: (a) Placing the food in shallow pans; (b) Separating the food into smaller or thinner portions; (c) Using rapid cooling equipment; (d) Stirring the food in a container placed in an ice water bath; (e) Using containers that facilitate heat transfer; (f) Adding ice as an ingredient; or (g) Other effective methods; (2) When placed in cooling or cold holding equipment, food containers in which food is cooling must be arranged so as to provide maximum heat transfer through the container walls and; loosely covered, or uncovered if protected from overhead contamination. Correct By: 31-Jan-2015
3717-1-02.3(A) / Food contamination prevention - eating, drinking, or using tobacco.
Observed employee drinks in food prep areas without protective lids.
To ensure proper hygiene, an employee shall eat, drink, or use tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils or linens; unwrapped single service or single use articles; or other items needing protection cannot result. This does not prohibit a food employee from drinking from a closed beverage container if the container is handled to prevent contamination. Correct By: 31-Jan-2015
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Equipment and/or components are not maintained in good working order. The plastic lids on the hand-dipped ice cream cooler are cracked and taped together, which poses a risk of physical contamination of food.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code. Owners are aware of issue and are seeking repair. Correct By: 27-Feb-2015 Correct By: 28-Feb-2015
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Non-food contact surfaces of equipment are dirty. Hoods above grill are greasy and require cleaning as often as necessary to remain clean.
Nonfood-contact surfaces of equipment shall be kept clean. Correct By: 06-Feb-2015
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 30-January-2015
Comments |
---|
Please work on developing proper cooling methods for chilli, soups, and other hot TCS foods cooled for reheating. Keeping a temperature log during cooling process will help ensure safe temperatures are being met in the time allowed. Shallow pans, ice baths, ice sticks, etc. are methods of rapid cooling that may help your process. We can go over these in detail during my reinspection in March. |