3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical TCS foods were not being held at the proper temperature. Cold holding of fish in the reach in cooler located by the fryers was not below required minimum of 41 degrees. Keep equipment maintained below required temperature of 41 degrees for cold holding.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-04.2(I) / Sanitizing solutions - testing devices.
Critical There is no test kit available for measuring the concentration of the sanitizer. Obtain quat test strips.
To ensure proper sanitization, a test kit or other device that accurately measures the concentration in PPM (mg/L) of sanitizing solutions shall be provided. Correct By: 17-Oct-2014
3717-1-04.4(N)(3) / Manual and mechanical warewashing equipment, using chemical sanitization - temp., pH, concentration, and hardness
Critical A quaternary ammonium sanitizing solution did not meet the minimum requirements for temperature, concentration, and/or water hardness. Concentration of sanitizer spray bottle was higher than 400 ppm. Maintain concentration of approximately 200 ppm.
To prevent pathogen growth, a quaternary ammonium sanitizing solution shall: (a) Have a minimum temperature of 75F,(b) Have a concentration as specified and as indicated by the manufacturer's use directions included in the labeling, (c) Be used only in water with 500 ppm (mg/l) hardness or less, or used in water having a hardness no greater than specified by the manufacturer's label. Correct By: 10-Oct-2014
3717-1-04.4(A)(2) / Equipment components kept intact, tight, and adjusted
Equipment components are not intact, tight or properly adjusted. Door seals of cooling units need replaced.
Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications. Correct By: 10-Oct-2014
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Observed a build-up of dirt and debris. Ice machine needs to be cleaned more frequently to prevent build up of mold
The physical facilities shall be cleaned as often as necessary to keep them clean, and cleaning shall be done during periods when the least amount of food is exposed. Correct By: 04-Oct-2014
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 03-October-2014
Comments |
---|
Continue to upgrade lighting in dish washing area. Dish tank sanitizer at 50 ppm and operating with adequate hot water for warewashing. Hot holding of food adequate and meeting required minimum. Overall kitchen was clean.Thank you. |