[?] A summary of the violations found during the inspection are listed below.

3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical Observed food that was not properly protected from contamination by separation, packaging, and segregation. Raw animal meat stored above ready-to-eat meatballs in meat display.
Food shall be protected from cross contamination by separating raw animal foods during storage, preparation, holding, and display from cooked ready-to-eat food as described in this rule.
3717-1-04.5(B) / Equipment food-contact surfaces and utensils - cleaning frequency.
Critical Food equipment surfaces are not cleaned at the required frequency. Nozzles at beverage station had built-up food residue.
Equipment food-contact surfaces and utensils shall be cleaned at a frequency specified in this rule.

3717-1-03.4(A) / Frozen food - temperature and time control.
Foods in frozen storage exhibit signs of thawing or refreezing. Frozen brauts were either not remaining frozen or re-freezing.
Stored frozen foods shall be maintained frozen.
3717-1-04.4(Q) / Utensils, temperature and pressure measuring devices - good repair and calibration.
Utensils, thermometers, and/or pressure guages were not kept in good repair or calibration. A couple of equipment temperature measuring devices throughout the store were not operational.
(1) Utensils shall be maintained in a state of good repair or shall be discarded; (2) Food temperature measuring devices shall be calibrated as necessary to esnure their accuracy; (3) Ambient air temperature, water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
3717-1-05.4(P) / Maintaining refuse areas and enclosures.
Observed an improperly cleaned storage area for refuse, recyclables, or returnables. A few bags of garbage were on the ground next to garbage receptable.
A storage area and enclosure for refuse, recyclables, or returnables shall be maintained clean and free of unnecessary items.


Inspection Information


Facility Type: Commercial RFE ≥ 25000 sq. ft.

[?] Inspection Type: Standard

Inspection Date: 11-September-2014


Comments
Overall, store is very well maintained and organized. Please thank the staff for their cooperation during the inspection.