Inspection Information | Facility Name: | Cinemark 14 |
---|---|
Facility Type: | Commercial FSO < 25000 sq. ft. |
[?] Inspection type: | Standard |
Inspection date: | 21-October-2022 |
Violations: A summary of the violations found during the inspection are listed below. |
3717-1-05.1(C)(1) / Handwashing sink - required water temperature Repeat Handwashing sink water below 100°F. Observed handwashing sinks in all restrooms to be 95*F. Ensure hanswashing sinks are minimum of 100*F for effective hand washing. Correct by next standard inspection. |
3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation Critical Corrected During Inspection Food not properly protected from contamination by separation, packaging, and segregation. Observed containers of popcorn and seasoning in cabinet below popcorn popping machines to be uncovered/not protected from contamination. PIC placed foil on top to cover during inspection. |
3717-1-04.5(B)(5) / Equipment food-contact surfaces and utensils - cleaning frequency. Repeat Utensils and equipment contacting non-TCS foods not cleaned at required frequency. Observed metal pieces where ice comes drops through into ice storage bin to contain visible white build up. Clean by 10-28-22. |
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking. Critical Corrected During Inspection Refrigerated, ready-to-eat, TCS foods not properly date marked. Observed opened bag of hot dogs in cooler without date mark. PIC discard bag of 2 hot dogs at time of inspection. |
3717-1-04.3(B) / Fixed equipment installation - spacing or sealing. Fixed equipment not properly sealed or spaced for cleaning. Observed seal along edges of mop sink to be missing and creating a small gap and not easily cleanable. Reseal by next standard inspection. |
3717-1-04.1(H) / Nonfood-contact surfaces - cleanability Nonfood-contact surfaces not easily cleanable. Observed candy storage drawers (one for cheetos & one for sour patch) near registers to have white laminate finish raised or peeling. Also observed laminate finish on edge of shelf in cabinet below self service butter station in lobby area to be missing and exposing bare wood. Reseal or repair by next standard inspection. |
3717-1-04.1(H) / Nonfood-contact surfaces - cleanability Nonfood-contact surfaces not easily cleanable. Observed metal shelving used to store soda syrup boxes to contain rust. Resurface or replace by next standard inspection. |
3717-1-04.1(H) / Nonfood-contact surfaces - cleanability Nonfood-contact surfaces not easily cleanable. Observed metal grates on dump basin of soda fountain machines near registers to contain rust. Resurface or replace by next standard inspection. |
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment. Non-food contact surfaces of equipment are unclean. Observed visible black residue on door seal of Beverage Air freezer holding frozen foods. Clean by 10-28-22. |
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment. Repeat Non-food contact surfaces of equipment are unclean. Observed excessive ice build up inside nestle ice cream freezer. Remove ice and clean by 10-28-22. |
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment. Repeat Non-food contact surfaces of equipment are unclean. Observed door tracks and white shelving inside coca cola cooler in lobby area to contain visible residue build up. Clean by 10-28-22. |
3717-1-04.5(D) / Nonfood-contact surfaces - cleaning frequency. Non-food contact surface(s) not cleaned at the required frequency. Observed gears on upper portion of both in use pop corn poppers to contain excessive butter build up. Clean by 10-28-22. |
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment. Non-food contact surfaces of equipment are unclean. Observed inside surfaces of butter station cabinet in satellite area to contain butter residue & spillage. Also observed inside surfaces of cabinet below Amana oven to contain visible residue. Clean by 10-28-22. |
3717-1-06.4(H) / Cleaning and maintenance of plumbing fixtures. Plumbing fixtures unclean. Observed faucets in women's restroom closest to lobby are to contain visible scale and residue build up. Descale/clean by next standard inspection. |
Comments |
---|
Inspection conducted with Amanda, PIC. Reviewed with Amanda and Tim, Manager. Facility is now selling canned and bottled alcohol beverages. Facility is also slicing limes and lemons. Discussed cleaning frequency of cutting board and knife needing to be every 24 hours or when visibly soiled. Facility does have new cooler for alcohol beverages and is expecting a new reach in cooler to replace broken cooler. Discussed emailing required spec sheets to Richland Public Health. Facility is holding sealed single serving cheese cups in warmer and discarding any leftover cheese ups at end of day. Inspection report emailed. |