Inspection Information | Facility Name: | Newswanger Meats |
---|---|
Facility Type: | Commercial RFE < 25000 sq. ft. |
[?] Inspection type: | Standard |
Inspection date: | 29-March-2023 |
Violations: A summary of the violations found during the inspection are listed below. |
3717-1-05.1(O)(1) / Using a handwashing sink - accessible at all times Critical Corrected During Inspection Handwashing sink not accessible. Observed handwashing sink to have a rod in the sink in the warewashing area. Ensure handwashing sink remains accessible and for no other use than handwashing. PIC removed rod at time of inspection. |
3717-1-07(B) / Poisonous or toxic materials: Working containers - common name. Critical Corrected During Inspection Working containers of poisonous or toxic materials not properly labeled. Observed quaternary ammonium in spray bottle near the handwashing sink to be unlabeled. Ensure all chemical working containers are labeled with at least the common name to avoid cross contamination. PIC had labeled at time of inspection. |
3717-1-03.5(C)(2) / Food labels - packaged food Corrected During Inspection Label on a food packaged in-house did not contain all required information. Observed tinted curing salt for individual sale be missing statement of responsibility. Ensure business name and full address including zip code are added to the packages. PIC had curing salt removed from sale until updated labeling information can be obtained. |
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment. Non-food contact surfaces of equipment are unclean. Observed vents in the reach in cooler to have visible residue. Clean by 4/5/2023. |
3717-1-05.4(N) / Covering receptacles. Repeat Waste receptacles not covered properly. Observed dumpster open at time of inspection. Ensure area is clean to prohibit the potential for pest harborage. Closed by end of day 3/30/2023. |
3717-1-06(B) / Outdoor areas - surface characteristics Repeat Improper outdoor surface characteristics. Observed dumpster to be placed on gravel rendering the surface no longer a smooth, durable, nonabsorbent, easily cleanable, and sloped to drain. Correct by next standard inspection. |
Comments |
---|
Conducted and reviewed with PIC. Emailed inspection. |