Inspection Information | Facility Name: | Madison Middle School |
---|---|
Facility Type: | Non-Commercial FSO < 25000 sq. ft. |
[?] Inspection type: | Standard |
Inspection date: | 06-May-2022 |
3717-1-02.4(C)(9) / PIC: duties - ensure employees are properly maintaining temperatures of TCS foods during hot and cold storage Critical Corrected During Inspection PIC did not ensure employees are proplerly maintaining temperatures of TCS foods during hot and cold storage. During inspection, two critical violations for not properly hot holding TCS foods were observed. during inspection CORRECTED, |
3717-1-05.1(O)(1) / Using a handwashing sink - accessible at all times Critical Corrected During Inspection Handwashing sink not accessible. At time of inspection, cart of bannanas was observed obstructing hand wash station. CORRECTED, listed item was relocated. |
3717-1-03.4(F)(1)(a) / Time/temperature controlled for safety food - hot holding. Critical Corrected During Inspection TCS foods not being hot held at the proper temperature. During inspection, meatloaf sandwich measured at 127 degrees F while on serving line. CORRECTED, listed iitems were removed from food line and reheated to over 165 derees F |
3717-1-03.4(F)(1)(a) / Time/temperature controlled for safety food - hot holding. Critical Corrected During Inspection TCS foods not being hot held at the proper temperature. During inspection, potato triangles were measured at 119 degrees F while on the serve line. CORRECTED, listed items were removed from serving line and reheated to over 165 degrees F. |
3717-1-04.2(I) / Sanitizing solutions - testing devices. No sanitizer test kit available. During inspection, no test strips for Purell sanitizer could be located. Please obtain proper test strips for sanitizer in use. |
3701-21-25(I) / Person in charge certification in food protection FSO did not have a person in charge per shift with the person in charge certification in food protection. During inspection, person with only certification was absent today. Please make sure several employees receive certification traaining in food preparation so that at least one person has PIC training per shift Certificaiton can be obtained on ODH website |
Comments |
---|
Conducted inspection with PIC Virginia Mason; reviewed inspection findings with PIC. Risk Level 3 activities include Cook/Serve. Menu consisted of pre cooked meatloaf, (hot hold), prepackaged applesauce, prepackaged carrots, potato wedges served hot, pasteurized dairy milk. Facility must make sure it does not Cook/Cool/Reheat/Hot Hold bulk quantities more than once over a seven day period or else it will need to be licensed as a Risk Level IV facility. |