Inspection Information | Facility Name: | Madison Middle School |
---|---|
Facility Type: | Non-Commercial FSO < 25000 sq. ft. |
[?] Inspection type: | Standard |
Inspection date: | 16-March-2023 |
3717-1-05.1(C)(1) / Handwashing sink - required water temperature Handwashing sink water below 100°F. During inspection, hand wash station across from walk in cooler measured at only 96 degrees F. Please adjust heat booster of sink to raise temperature |
3717-1-04.4(Q)(2) / Utensils, temperature and pressure measuring devices - good repair and calibration. Utensils, thermometers, and/or pressure gauges not in good repair or calibrated. During inspection, center Traulsen hot hold unit gauge measured 154 degrees F when actual temperature measured 138 degrees F Please calibrate equipment regularly so gauge will represent actual conditions |
3717-1-04.1(Y) / Temperature measuring devices. Corrected During Inspection Hot and cold holding equipment thermometer was missing, located incorrectly, or not easily readable. During inspection, thermometers were not located in steam tables of both lines. CORRECTED, thermometers were placed in lisited areas |
3717-1-06.4(B) / Cleaning - frequency and restrictions. Repeat Corrected During Inspection Facility not maintained clean. During inspection, ice cycles observed under walk in cooler condenser fan CORRECTED, ice removed |
Comments |
---|
Conducted inspection with PIC; reviewed inspection findings with PIC. Risk Level 3 activities include: Cook/Serve. Menu consisted of precooked pancakes, sausage (hot hold), precooked potato wedges (hot hold), pasteurized dairy milk. |