Inspection Information | Facility Name: | Woodland Elementary |
---|---|
Facility Type: | Non-Commercial FSO < 25000 sq. ft. |
[?] Inspection type: | Standard |
Inspection date: | 26-October-2022 |
3717-1-05.1(C)(1) / Handwashing sink - required water temperature Repeat Handwashing sink water below 100°F. During inspection, employee hand wash station only provided 72 degree F hot water after being run for over 60 seconds Please adjust heat booster so that hot water measures at least 100 degrees F |
3717-1-04.5(B)(1) / Equipment food-contact surfaces and utensils - cleaning frequency. Critical Repeat Corrected During Inspection Food equipment surfaces not cleaned at required frequency. During inspection, worker measured brocoli without sanitizing food contact surface of probe thermometer. CORRECTED, worker used alcohol swab to sanitize thermometer |
3717-1-03.4(F)(1)(b) / Time/temperature controlled for safety food - cold holding. Critical Corrected During Inspection TCS foods not being cold held at the proper temperature. During inspection, "First Fridge" 2 door Traulsen cooler had milk inside that measured 51 degrees F. CORRECTED, PIC discarded 30 one pint portions of milk. |
3717-1-04.4(Q)(2) / Utensils, temperature and pressure measuring devices - good repair and calibration. Utensils, thermometers, and/or pressure gauges not in good repair or calibrated. During inspection, Hobart 2 door cooler near kitchen office measured 38 degrees F and not actual 34 degrees F. Please schedule regular calibration of all temperature measuring devices |
3717-1-04.4(Q)(2) / Utensils, temperature and pressure measuring devices - good repair and calibration. Utensils, thermometers, and/or pressure gauges not in good repair or calibrated.During inspection, "First Fridge" Traulsen 2 door cooler registered 41 degrees F when actual internal ambient temperature was 51 degrees F Please schedule regular calibration of all mechanically cooled equipment |
3717-1-04.4(Q)(2) / Utensils, temperature and pressure measuring devices - good repair and calibration. Utensils, thermometers, and/or pressure gauges not in good repair or calibrated. During inspection, Hobart 2 door freezer registered 10 degrees when actual temperatures was -4 degrees F Please calibrate temperature reading devices of all mechanically cooled equipment |
3717-1-04.1(H) / Nonfood-contact surfaces - cleanability Repeat Nonfood-contact surfaces not easily cleanable. During inspection,, aluminum cart in dry goods room observed dented and no longer smooth and cleanable Please repair or replace cart so that there are smooth surfaces for proper cleaning |
Comments |
---|
Conducted inspection with PIC Beth Hutchinson; reviewed inspection findings with PIC. Risk Level 3 activities include Cook/Serve. Menu consisted of Pre cooked pizza (hot hold), cooked broccoli (hot hold), frozen prepackaged strawberry desert, pasteurized dairy milk |