3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Observed the ORP to be 330 millivolts.
Have the ACC unit inspected to determine why the ORP is low. The pool's ORP will need to be maintained at or above 650 millivolts.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Observed some of the ladders to easily shake and rattle.
Repair or replace the ladders so that they are secure and do not easily shake and rattle.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Observed the pH to be approximately 8.0.
Treat the pool so that the pH is maintained between 7.2 and 7.8.
3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Observed the pool's free chlorine to be 0ppm. Did not observe any free chlorine in the pool.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 29-August-2023
Comments |
---|
At time of inspection person in charge contacted pool maintenance. Person in charge stated that they would keep the pool closed until pool maintenance has been on site and until inspector can verify that at least 1.0 ppm free chlorine is detected. Will conduct follow-up inspection same day at a later time. |