Inspection Information | Facility Name: | WILLIAMS COUNTY FAMILY YMCA |
---|---|
Facility Type: | Spa |
[?] Inspection type: | Standard |
Inspection date: | 21-August-2019 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 ( D )(6)(a) ORP reading was below 650 mv. ORP reading at the time of inspection was 434 mv. Have the ACC unit inspected to determined why the ORP is low. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. pH was measured to be 7.0. Treat the pool water so that the pH is within the acceptable range. |
3701-31-04 (C)(3) Total alkalinity was less than 60 ppm. Total alkalinity was measured at 30 ppm. Raise the total alkalinity to at least 60 ppm. |
3701-31-04(D)(6)(a)(1) Combined chlorine was greater than 1.0 ppm. Testing revealed combined chlorine to be at 2.0 ppm. Treat the pool so that the combined chlorine is less than 1 ppm. |
Comments |
---|
Keep an eye on the temperature of the spa water, as it is getting close to exceeding the temperature limit of 104 degrees. |