Inspection Information | Facility Name: | BOB MOR INC DBA QUALITY INN |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 29-August-2019 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 ( D )(6)(a) ORP reading was below 650 mv at the time of inspection, reading at 455 mv. Have the ACC unit inspected to determined why the ORP is low. |
3701-31-04 (B)(1)(c) Critical Disinfection residual was less than 1 ppm. Free chlorine was measured to be 0.4 ppm |
3701-31-04 (B)(1)(e) Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation. |
3701-31-04 (B)(4) The licensee /authorized representative was not keeping or maintaining operational records. Records had not been kept for over 2 months. All facility records must be maintained and available for review upon request. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. pH was measured at 7.0. Treat the pool water so that the pH is within the acceptable range. |
Comments |
---|
It was recommended the pool be closed due to critically low disinfection residuals until water chemistry could be normalized. |